USB4000-UV-VIS Miniature Fiber Optic
Spectrometer
The USB4000-UV-VIS is preconfigured for applications from 200-850
nm. The USB4000-UV-VIS features a 3648-element Toshiba linear CCD array
for increased signal-to-noise and enhanced electronics for
controlling the spectrometer and accessories.
--Available for immediate delivery! --
Features
The USB4000-UV-VIS Spectrometer is
pre-configured with the DET4-200-850 detector and order-sorting filter
to cover the 200-850 nm wavelength range. The spectrometer comes with a
multi-bandpass order-sorting filter and a 25 µm entrance slit
for optical resolution to ~1.5 nm (FWHM).
Programmable Microcontroller
The USB4000-UV-VIS onboard programmable microcontroller provides you with
considerable flexibility in controlling the spectrometer and accessories.
Through a 22-pin connector, you can implement all operating parameters in
the software: control light sources, create processes, and retrieve
information on external objects. You have access to 8 user-programmable
digital Inputs/Outputs for interfacing to other equipment. (Contact an Applications Scientist regarding what you'll need to
program the GPIOs.)
Optimal
Performance
The USB4000-UV-VIS provides you with an affordable, high-performance 3648-element linear CCD-array
detector with an optical bench that's small enough to fit into the palm of
your hand. The USB4000-UV-VIS works the same way as other Ocean Optics spectrometers; it accepts light energy transmitted through single-strand optical
fiber and disperses it via a fixed grating across the linear CCD array
detector, which is responsive from 200-1100 nm.
Modular Design
When you purchase a
USB4000-UV-VIS,
you can also choose from Ocean Optics'
complete line of spectroscopic accessories. Most
accessories have SMA 905 connectors for application flexibility. Changing the
sampling system is as easy as unscrewing a connector and adding new
components or accessories, such as light sources, sampling holders, filter
holders, flow cells, fiber optic probes and sensors, collimating lenses,
attenuators, diffuse reflectance standards, integrating spheres and our
extensive line of optical fibers.
Plug and Play Operation
The USB4000-UV-VIS interfaces to a PC, PLC or other embedded controllers via USB 2.0
or RS-232 serial port. When using the serial port, the USB4000-UV-VIS
requires a single 5-volt power supply (not included). Data unique to each
spectrometer is programmed into a memory chip on the USB4000; our
spectrometer operating software reads these values for easy setup and hot
swapping among PCs.
Serial
port operation tips: When using the serial port, the USB4000-UV-VIS
requires a single 5-volt power supply (not included). Also, SpectraSuite
Spectroscopy Software does not support spectrometer operation via the
serial port. However, using the included Serial Port Command Set, you
can write your own software that makes serial port operation possible.
Specifications
|
Physical
|
|
Dimensions: |
89.1 mm x 63.3 mm x 34.4 mm |
|
Weight: |
190 grams |
|
Detector Specifications |
|
Detector:
|
Toshiba TCD1304AP Linear CCD array |
|
Detector range: |
200-1100 nm |
|
Useable range: |
200-850 nm |
|
Pixels:
|
3648 pixels |
|
Pixel size:
|
8 μm x 200 μm |
|
Pixel well depth:
|
100,000 electrons |
|
Signal-to-noise ratio: |
300:1 (at full signal) |
|
A/D resolution: |
16 bit |
|
Dark noise: |
50 RMS counts |
|
Corrected linearity: |
>99.8% |
|
Sensitivity: |
130 photons/count at 400 nm; 60 photons/count
at 600 nm |
|
Optical Bench |
|
Design: |
f/4, Asymmetrical crossed Czerny-Turner |
|
Focal length: |
42 mm input; 68 mm output |
|
Entrance aperture: |
25 µm wide slit |
|
Grating: |
Grating #1 (blazed at 300 nm) |
|
OFLV filter: |
OFLV-200-850 |
|
UV enhanced window: |
Yes, UV4 |
|
Fiber optic connector: |
SMA 905 to 0.22 numerical aperture single-strand optical fiber |
|
Spectroscopic |
|
Wavelength range: |
200-850 nm |
|
Optical resolution: |
~1.5 nm FWHM |
|
Signal-to-noise ratio: |
300:1 (at full signal) |
|
A/D resolution: |
16 bit |
|
Dark noise: |
50 RMS counts |
|
Integration time: |
3.8 ms to 10 seconds |
|
Dynamic range: |
2 x 108
(system), 1300:1 for a single acquisition |
|
Stray light: |
<0.05% at 600 nm; 0.10% at 435 nm |
|
Electronics |
|
Power consumption: |
250 mA @ 5 VDC |
|
Data transfer speed: |
Full spectrum to memory every 5 ms with USB 2.0 port |
|
Inputs/Outputs: |
Yes, 8 onboard digital user-programmable GPIOs |
|
Breakout box compatible: |
Yes, HR4-BREAKOUT |
|
Trigger modes: |
4 modes |
|
Strobe functions: |
Yes |
|
Connector: |
22-pin connector |
|
Computer |
|
Operating systems: |
Windows 98/Me/2000/XP, Mac OS X and Linux
with USB port; Any 32-bit Windows OS with serial port |
|
Computer interfaces: |
USB 2.0 @ 480 Mbps (USB1.1 compatible);
RS-232 (2-wire) @ 115.2 K baud |
|
Peripheral interfaces: |
SPI (3-wire); I2C inter-integrated circuit |
|
Pricing |
|
Retail: |
$3061 |
PRODUCTS |
TECHNICAL |
APPLICATIONS |
CORPORATE |
DISTRIBUTORS
| PRIVACY POLICY
CONTACT US |
CATALOG |
PRICE LIST |
ORDER INFO

.
©2007 Ocean Optics, Inc. All rights reserved.
Terms of
Use and Privacy Statement
+1
727.733.2447 • +1 Fax 727.733.3962 •

|
|
Contact an Ocean Optics
Applications Scientist
Convenient Wavelength Calibration!
Click here for Details
|